This project example shows a D40 Ventilation Hood for Underground Garage Ventilation of an office complex in northern Hamburg. The existing shaft opening was part of the project-specific ventilation design and was used for air distribution.
However, the horizontal grating did little to keep rain, snow, and leaves out of the shaft. For this reason, rotec developed a weather-optimized ventilation hood as a custom design specific to the project.
The D40 ventilation hood directs air over the side slats. At the same time, the slightly curved roof channels precipitation to the sides. This article explains the initial situation, the structural design, and key planning requirements.
The Most Important Points at a Glance
- rotec developed and installed the D40 ventilation hood as a custom design tailored to the project.
- Side fins provide the necessary airflow.
- The slightly curved roof directs rainwater to the sides.
- The supporting structure is made of hot-dip galvanized steel.
- The louvered grilles and roof surfaces are made of aluminum.
- The clear cross-sectional area must be checked once the structure is complete.
- The suitability of natural, mechanical, or combined ventilation must be demonstrated on a project-by-project basis.
- All project images shown are original photographs of completed rotec projects.
Additional Technical Articles on the Design of Ventilation Hoods
This project showcases a custom solution implemented using the D40 ventilation hood. Other technical articles cover technical planning, greening, and additional potential uses.
Table of Contents
- Project Example from Hamburg
- Initial Situation at the Office Complex
- The Solution with the D40 Ventilation Hood
- Structural Design of the Ventilation Hood
- Side Airflow and Weather Protection
- Protection from leaves, insects, and small animals
- Materials and Corrosion Protection
- Safety and Maintenance
- When is natural underground garage ventilation appropriate?
- Lessons Learned from rotec's Planning Practice
- Important Information for Planning
- Other Implementation Options
- Frequently Asked Questions About the D40 Ventilation Hood
- Conclusion on the Project Example
Project Example from Hamburg
Important Note: The ventilation hood shown here was designed for a specific installation scenario. Its dimensions, materials, and design details cannot be applied to other construction projects without prior review.
Known Project Data
- Property: Office complex in northern Hamburg
- Component: Project-specific D40 ventilation hood for an existing shaft opening
- Construction: hot-dip galvanized steel substructure, side slatted grilles, and a slightly curved aluminum roof surface
- Scope of Services: Development of the custom design and installation by rotec
- Images: exclusively original photographs of completed rotec projects
Note: Dimensions, air flow rates, and other technical parameters are no longer fully documented in the project documents currently available. Therefore, no values will be estimated retroactively.

The canopy is located within a green space next to the office building. This makes it easily accessible while also allowing it to blend into the outdoor area.
The side slats allow air to circulate. At the same time, the enclosed roof surface protects the shaft below from direct precipitation.
Initial Situation at the Office Complex
The existing ventilation shaft was located within a green space next to the building. Originally, horizontally arranged grates covered the shaft opening.
Although this design allowed for the necessary air exchange, rain, snow, and leaves fell directly into the horizontal opening.
Therefore, the goal was to develop a design with lateral airflow. It was also intended to reduce direct exposure to the elements and complement the architecture.
Requirements for the new range hood
- Use of the existing shaft opening
- Adequate lateral ventilation areas
- Controlled drainage of precipitation
- weather-resistant exterior components
- stable substructure
- accessible maintenance areas
- Minimal impact on the existing outdoor facilities
- Design harmony with the building
Ventilation hood for the underground parking garage: the D40 solution
Rotec developed a D40 ventilation hood for the existing shaft opening. A steel substructure supports the side louver grilles and the upper roof surface.
Air flows over the slats arranged on the sides. The enclosed roof surface, on the other hand, protects the shaft opening from direct precipitation.
The design was not selected from a fixed size grid. Instead, rotec adapted it to the shaft dimensions, air clearances, and installation conditions.
The project-specific custom structure was installed by rotec.

Structural Design of the Ventilation Hood
The ventilation hood consists of a load-bearing substructure, side louver grilles, and a closed roof surface. Each component serves a specific purpose.
| Component | Design | Function |
|---|---|---|
| Substructure | hot-dip galvanized steel structure | Load transfer and support of exterior components |
| Louvre grille | Aluminum | Side airflow and privacy screen |
| Roof area | slightly domed aluminum cover | Calculation of Precipitation for Each Page |
| Shaft Connection | project-specific adjustment | Connection between the structure and the ventilation hood |
Profile dimensions, fasteners, and material thicknesses must be specified separately for each project. Wind loads, location, canopy size, and building connections all influence the design.
Modular design for transport and assembly
A modular design can simplify transportation and installation. Larger ventilation hoods can be delivered in several pre-assembled sections.
The layout depends on transportation routes, lifting capabilities, and accessibility to the installation site. For this reason, the installation plan should be finalized during the design phase.
Side Airflow and Weather Protection
Air flows through the side louver grilles. The external dimensions of the range hood are not a determining factor in this regard.
The key factor is the actual usable clear cross-sectional area. Frames, slats, spacer profiles, and protective grilles reduce the usable ventilation area.
Therefore, the design must take into account the system's complete installed configuration. This is the only way to reliably evaluate airflow and pressure drop.
The slightly curved roof directs rainwater toward the outer edges. Connections, slopes, and drip edges must ensure that the water continues to drain properly.

A range hood is not a watertight structure
The enclosed roof surface reduces the amount of direct precipitation entering the building. The side slats also deflect some of the water that strikes the roof.
However, this does not mean that the product is completely waterproof. Wind, airspeed, slat geometry, and installation orientation all affect its rain protection.
For more information, see the technical article
Ventilation Grilles and Rain Protection in Accordance with DIN EN 13030
.
Planning Note: Weather protection louvers remain air-permeable components. Therefore, water runoff, shaft drainage, and local weathering must be considered together.
Protection from leaves, insects, and small animals
Depending on the location, additional protection may be required behind the slats. Possible solutions include grating, perforated metal sheets, or suitable protective mesh.
However, additional protective layers reduce the clear cross-sectional area. Fabrics with particularly fine weaves also increase flow resistance.
Dust, leaves, and plant debris can clog protective netting over time. Therefore, the netting must be accessible, easy to inspect, and replaceable when necessary.
Stainless Steel Fly Screen
A stainless steel fly screen can make it harder for insects and small animals to get in. However, the mesh size must be appropriate for the required airflow.
The clear cross-sectional area of the gauze must therefore be included in the ventilation calculations. In addition, the design must provide easily accessible access for cleaning.
rotec Recommendation: Protective screens should be mounted in removable frames whenever possible. This makes it possible to clean them or replace them without having to take them apart extensively.
Materials and Corrosion Protection
In this project, the louver grilles and the roof covering are made of aluminum. Their light weight makes it easier to handle the individual components.
Aluminum offers good natural corrosion resistance. In addition, a coating can match the surface color to that of the building.
The load-bearing substructure is made of hot-dip galvanized steel. As a result, the structure combines load-bearing capacity with adequate corrosion protection for outdoor use.
However, the choice of materials must be appropriate for the specific corrosion conditions. In addition, contact points between aluminum and steel must be taken into account in the design.
Select surfaces based on the project
The visible aluminum components can be left uncoated or coated. Powder coating offers a wide range of colors and finishes.
The color and surface texture should be determined early on. This makes it easier to coordinate the slats, the roof surface, and adjacent facade elements.
Safety and Maintenance
The enclosed roof surface and the side slats make it difficult to gain direct access to the shaft opening. However, they are not a substitute for project-specific safety planning.
Fall protection, traffic safety, and vandalism protection must be evaluated separately. In doing so, usage, accessibility, and local hazards must be taken into account.
A closed top surface is not automatically accessible. If the surface is intended to be accessible, it must be designed accordingly in terms of structural integrity and construction.
Plan for maintenance access early on
It must be possible to inspect fin surfaces, roof connections, and interior areas. Therefore, maintenance access should be determined during the planning phase.
Possible solutions include maintenance doors, removable louvered panels, or separate access panels. However, they must not compromise the stability or airflow performance.

When is natural underground garage ventilation appropriate?
Natural ventilation may be appropriate if the building's geometry and ventilation openings allow for it. In addition, the requirements of building codes must be met.
Wind pressure, thermal lift, and pressure differences are what create air movement. The location and size of the openings therefore affect their effectiveness.
Other key factors include the required air volume, the clear cross-sectional area, and the fire protection plan. Suitability must be assessed separately for each construction project.
A mechanical ventilation system may still be necessary. This is especially true if natural airflow cannot reliably provide the required air volume.
Combined systems are also possible. The D40 ventilation hood can protect a shaft opening while allowing for lateral airflow.
However, the ventilation hood does not replace a ventilation or fire safety certification.
Note for projects in Hamburg: According to Section 16 of the Hamburg Garage Ordinance, enclosed medium- and large-sized garages generally require a mechanical exhaust ventilation system. Natural ventilation is permitted only under the conditions described therein. Therefore, the type of ventilation, clear cross-sectional area, and supporting documentation must always be determined on a project-by-project basis by the responsible design engineers and the relevant authorities. § 16 of the Hamburg Garage Ordinance (GarVO) on Garage Ventilation
Distinguishing Between Natural and Mechanical Ventilation
| Planning aspect | Natural Ventilation | Mechanical Ventilation |
|---|---|---|
| Air Movement | due to wind pressure, thermal lift, and pressure differences | by fans |
| Ventilation openings | openings that are sufficiently large and properly spaced | Dimensions Based on Air Volume and System Design |
| Energy Requirements | No direct fan operation for air circulation | Electric power requirements for fans and controls |
| Proof | Project-Specific Ventilation Analysis | Project-Specific Equipment Sizing |
| Dependencies | Geometry, Weather Conditions, and Arrangement of the Openings | Fans, ductwork, control systems, and power supply |
Lessons Learned from rotec's Planning Practice
For existing underground parking garage shafts, the clear external dimensions are not sufficient for planning purposes. Frame profiles, slats, and protective grilles reduce the actual usable cross-sectional area.
That is why rotec first assesses the required air intake area and the existing shaft geometry. Next, it considers the roof shape, the arrangement of the louvers, and maintenance access.
For retrofits, the seal, the manhole rim, and existing mounting options must also be checked. Accessibility to the installation site is also a key factor.
These factors influence the final design. They also determine whether rotec will deliver the hood pre-assembled or in several separate sections.
Planning sequence: First, the airflow capacity and clear cross-sectional area are determined. Next come the louvers, substructure, roof shape, maintenance access, and surface design.
Important Information for Planning
A ventilation hood should not be selected based solely on the external shaft dimensions. Rotec requires additional information to conduct a technical review.
| Planning Area | Required Information | Implications for Design |
|---|---|---|
| Shaft opening | Length, Width, Height, and Location | Basis for Dimensions and Building Connections |
| Airflow | Supply air, exhaust air, or combined use | determines the flow conditions and the required fin area |
| Airflow | Airflow or required clear cross-sectional area | Basis for sizing the hood |
| Weather protection | Weathering and Desired Protective Effect | affects the type of slats and water drainage |
| Protective grille | Protection against insects, leaves, or small animals | reduces the clear cross-sectional area |
| Security | Accessibility, Fall Protection, and Vandalism Protection | affects design and fastening |
| Maintenance | Door size, opening direction, and clearance | ensures long-term access |
| Surface | Material, Color, and Corrosion Exposure | determines the design and corrosion protection |
| Mounting | Access, crane availability, and transport routes | affects component size and delivery strategy |
Configure Custom Ventilation Grilles
For individual ventilation grilles and weather protection grilles, the
rotec Online Configurator for Ventilation Grilles
available.
Project-specific ventilation hoods, such as the D40, on the other hand, are designed on a case-by-case basis. In this process, the shaft, airflow capacity, substructure, and roof design must all be considered together.
Additional Design Options for Ventilation Hoods
The D40 ventilation hood features a classic design with a domed roof and side louvers. Depending on the project, other solutions are available.
- Ventilation hoods with integrated green roofs
- Roof hatches with wooden supports serving as seating
- Models with separate backrests
- Flaps for enhanced rain protection
- Soundproofing louvers for noisy equipment
- Poke-proof slats for accessible areas
- Burglar-resistant ventilation grilles for situations requiring enhanced protection
- Project-Specific Maintenance Doors and Inspection Openings

The Article
Ventilation hoods as street furniture
shows additional solutions featuring seating, backrests, and green roofs.
The article describes a completed project involving a planting design
Underground garage ventilation with green roof hood
.
Frequently Asked Questions About the D40 Ventilation Hood
Is the D40 range hood a standard product?
The D40 ventilation hood shown here was manufactured as a custom design tailored to this specific project. The dimensions, louver areas, and roof structure are adapted to the construction project.
Can the hood be used for both supply and exhaust air?
The basic design can be adapted for various air distribution applications. Its suitability depends on the airflow rate, duct geometry, and ventilation concept.
Does the skylight completely prevent water from entering?
No. The roof surface and slats reduce the amount of direct precipitation that enters. However, wind, air velocity, and the installation orientation can still cause water to enter through the openings.
Can an insect screen be installed behind the slats?
Yes. Protection against insects or small animals is generally possible. However, the protective covering reduces the clear cross-sectional area and requires access for cleaning.
Is the range hood accessible?
Access to the roof is permitted only if it has been designed to meet the appropriate structural and safety requirements. A closed roof surface is not automatically accessible.
Can the cover be retrofitted to an existing shaft?
Retrofitting is generally possible. However, the edge profile, load-bearing capacity, sealing, air surfaces, and installation conditions must be checked beforehand.
What information does rotec need for an initial review?
We need shaft dimensions, drawings, and information on airflow or clear cross-sectional area. Information on roof construction, maintenance, and surface finish is also helpful.
Does the range hood replace the ventilation verification?
No. The ventilation hood is a component of the ventilation system. The required documentation regarding ventilation and fire protection remains necessary on a project-by-project basis.
How is the clear cross-sectional area of a range hood determined?
The external dimensions are not the determining factor. Frames, louvers, spacer profiles, and protective grilles reduce the usable ventilation area. Therefore, the clear cross-sectional area must be calculated based on the fully installed condition and compared with the required airflow rate.
What are the requirements for natural underground garage ventilation in Hamburg?
The requirements are set forth in particular in Section 16 of the Hamburg Garage Ordinance. Whether natural ventilation is permitted depends, among other things, on the garage’s size, intended use, ventilation openings, shaft layout, and the required documentation. The assessment must be made on a project-by-project basis.
Who installed the D40 ventilation hood for the Hamburg project?
The D40 project-specific ventilation hood was installed by rotec. The custom design was adapted to fit the existing shaft opening and the on-site installation conditions.
Are the images original photographs?
Yes. All of the project images shown in this article are original photographs of completed rotec projects. The photographs document the structural design, the slat surfaces, and the installation conditions.
Conclusion on the Project Example
The D40 Ventilation Hood for Underground Garage Ventilation shows a project-specific solution for an existing shaft opening.
Side slatted grilles allow air to circulate. At the same time, the closed, slightly curved roof reduces the direct entry of precipitation.
The structure combines aluminum components with a hot-dip galvanized steel substructure. The materials and dimensions were tailored to the specific installation conditions on site.
The clear cross-sectional area, the connection to the structure, drainage, and access for maintenance remain critical factors. These points must be determined during the planning phase.
The ventilation hood does not replace a ventilation or fire safety analysis. It is a component of the ventilation system that must be designed on a project-by-project basis.
Planning a ventilation hood for an underground parking garage or a utility shaft?
Please send rotec the most accurate shaft dimensions, floor plans, and cross-sections possible. We also need information on the air volume or the clear cross-sectional area.
Information regarding the roof structure, maintenance access, and desired weather protection facilitates the technical inspection.